Lubricant Dispensing and Storage Systems

Larry King, IFH Group Inc.
Tags: lubricant storage and handling

A new lubricant dispensing and storage system complements lube room procedures.

Beaver Valley Power Station (BVPS) is a nuclear power plant near Shippingport, Pa., 34 miles from Pittsburgh. The plant has two Westinghouse pressurized water reactors capable of producing 970 and 920 megawatts of power, respectively. It is owned by First Energy Nuclear Operating Corporation. Unit 1 has been in commercial operation since 1976, and Unit 2 commenced commercial operation in August 1987.

The plant's location on the Ohio River has the historic significance of being on the site of the United States' first nuclear power plant, which went into service on December 2, 1957. It generated 60 megawatts of electricity at full power, according to Tyrone Turner, supervisor of the tool room and metrology lab at BVPS.

In a modern, large-scale facility such as BVPS, there is large amount of machinery (such as turbines, diesel generators and a vast array of pumps), all of which require lubrication.

"Every pump and gear case in the plant requires its own lubricant," said tool room attendant Ted Kubera.

Now in his 30th year with BVPS, Kubera is in charge of the daily operation of the oil room, located within the tool room area at the plant. Because security is a priority, access to this secure room is restricted.

"The tool room is always locked when unoccupied," Kubera said. And because the oil room is located within the heated tool room, the oil is not only secure, but is also warm and ready to use.

Making sure that every piece of machinery in the plant receives the right lubricant is critical, and it's important that the oil is fresh, clean and free of contaminants. A variety of premium-performance circulating lubricant oils of different grades and weights are stored in a custom-designed lubricant storage and lubricant dispensing system manufactured by The IFH Group, Inc. of Rock Falls, Ill. The system was sold to BVPS by M.W. Byers Company in Carnegie, Pa., which helped BVPS custom design the system and install it in 2001.

Lubricant Dispensing

Figure 1. A 24-container Lubricant Dispensing System

Before

The lubricants are delivered in 55-gallon drums wheeled into the oil room. Before installation of the IFH system, the lubricants had been dispensed from 55-gallon drums with spouts mounted on racks. The drums had to be laboriously hauled up onto the racks and dispensed from the drums and, according to Kubera, "It wasn't filtered. Oil drums were reused by the manufacturer and could contain contaminants."

After

Now, the 55-gallon drums are delivered into the oil room and the oil is pumped into the containers in the lubricant dispensing system, which is arranged in two rows, one on top of the other, of 12 containers each (Figure 1). Each of the 24 lightweight 65-gallon capacity aluminized steel containers holds a different oil, and is clearly labeled with the name and grade of the product.

Quick-coupling Filter Assembly

Figure 2. Quick-coupling Filter Assembly

The 10 gallons of additional capacity that each container holds enables all of the product to be pumped out of the 55-gallon drums and into the system. Each container also has a sight gauge that clearly shows the level of lubricant in it. This feature makes inventory control easier and eliminates the need to have extra product standing by.

Container with MSDS Label

Figure 3. Container with MSDS Label

"The container system was easy to put up," Kubera said. "The lubricant dispensing manifold, drip pan, pump, motor and timer came preassembled and tested from the factory, and we were able to assemble and install it fairly quickly. It has made pumping product a lot easier, and it has a nice, clean, orderly appearance."

Poly Containers

Figure 4. Poly Containers

No Cross-contamination

A key reason for the installation of the system was to prevent cross-contamination. A product is filtered as it is pumped into the numbered containers by the quick-coupling filter assembly through a corresponding numbered valve arrangement underneath the containers (Figure 2). This helps to ensure that the lubricant the technician is getting is exactly what has been requested.

Drip pans contain all spills. In place of the standard screened vents, each row of tanks has the vent fittings piped to a desiccant breather installed on the side of the container system, one per row. This way, whatever contaminants that may be in the ambient air (especially moisture) are not drawn into the containers when the oil is discharged. This ensures that the air entering the containers is always clean.

"Cross-contamination from one type of oil to another is one of the biggest problems," Kubera said. "We ensure that no two different oils from different families ever touch each other." With this system in place, the oil is filtered at three microns.

The plant prides itself on the detailed procedures it has in place to make sure the wrong lubricant is never dispensed.

Electronic Lube Manual

"We created a comprehensive Electronic Lube Manual (ELM) that ensures procedures are followed down to the last detail," Kubera said. "Before we issue any oil, we have to see a work order that shows what system the requested lubricant is for. Every component has an asset number; this process requires the technician requesting any lubrication to have documentation. The ELM database uses the asset number to identify all approved lubrications for that component. We then look up the asset number using the ELM, which tells us exactly what type of oil is needed for that component. Using the ELM ensures that the correct lubrication matches the lubricant requested."

Prior to leaving the issue point, a Material Safety Data Sheet (MSDS) label containing the product name, grade (heavy, medium, light, etc.), the manufacturer, chemical makeup and combustibility rating is printed. In addition, the MSDS information addresses any restrictions (Figure 3).

Peer Check

"During lubricant dispensing, we use a two-person peer check process," Kubera said. "We check the name of the oil and the label on the container and the dispensing valve, then a second person performs the same checks to ensure we have the right spout. When the technician and the tool room attendant leave the oil room, I know we have the right oil, and that it's clean and not cross-contaminated with any other oil or other potential contaminants. We never reuse containers or funnels. We use new containers for dispensing oil to ensure cleanliness and eliminate cross-contamination."

The 24-container system is used for everyday oils, Kubera said. For less frequently used lubricants, the plant installed a 10-container system in 2006 that employs 15-gallon capacity containers made of polyethylene (Figure 4).

For seldom-used oils not stored in the IFH containers, Kubera devised a security tag that is placed on the 55-gallon drums in which they are stored. No one can help themselves to the contents of any of these drums without breaking the seal; therefore, this process ensures positive control.

Waste oil is stored in flammable waste cabinets located within the tool room outside the oil room. Each waste container contains two 55-gallon barrels. All oily waste by-products are disposed in specially marked bags and then removed from the tool room.

Beaver Valley's process for the lubricant storage and lubricant dispensing has made it a model plant that First Energy plans to initiate in its other plants.

About the Author

Larry King is Midwest regional sales manager for The IFH Group, Inc. To learn more, visit www.ifhgroup.com.