Used Filter Testing Equipment for Sale

Noria Corporation

Multi-pass Filtration Performance Test Stand (10-50 gpm)

The multi-pass filtration performance test stand is used to evaluate the filtration performance of a fluid filter in accordance with ANSI Standard B93.31-1973 and ISO 4572. This test stand is a self-contained unit that incorporates fluid reservoirs and filter test systems. Doors in front, sides, and back permit access to the stand interior for inspection and maintenance.

This test stand consists of three circuits

1.  Circuit 1 (System Circuit) is a main filter test circuit capable of supplying a controlled flow rate of 10-50 gpm (38-190 lpm) at a maximum filter differential pressure of 150 psid (6.8 bar). 

2.  Circuit 2 (Injection Circuit) is a contaminant injection system capable of injecting a controlled contaminant slurry into the filter test system at variable flow rates (0.25-1.0 liter/min). The system is capable of injection for over 200 minutes. This flow is indicated by a rotameter. Circuits 1 and 2 each contain an independent clean-up circuit consisting of housings containing two filter elements. The recommended filter elements should exhibit an average 10-micrometer filtration ratio in excess of 500 and an ACFTD capacity of over 350 grams.

3.  Circuit 3 (Fill/Drain Circuit) is a fluid transfer system capable of filling the systems at the rate of approximately 4.0 gpm (15 lpm). The fluid storage reservoir has a volume of approximately 115 liters (30 gallons).

This stand can also serve as the filter test system and contaminant injection system for ISO 16889 by connecting the upstream and downstream sampling ports of the test filter to an automatic particle counting system

Additional Information

 

Required Connections

Electrical:220 volt, 3 phase, 60 Hz, 60 amps with an external ground.

Cold Water:Minimum 6 gpm at 60-70°F. Connection located at the middle right rear of the test stand.

Steam:Minimum 60-65 psig source. Connection located at the right rear bottom of the stand.

Water Drain:Connection (1/2” NPTF) located at the upper right rear of the test stand.

Width

50 inches

Length

76 inches

Height

80 inches

Weight

~ 2500 pounds

 

Unit Schematic

Panel Layout

Instrument Layout

This item is sold on an “as-is” basis. The seller makes no claims, representations, or warranties, whether express or implied, as to the quality or the functionality of the item. Furthermore, the seller accepts no liability for the item's safety, reliability, durability, or performance and is not responsible for any physical harm or damage to property as the result of using the item. By purchasing this item, the buyer absolves the seller of any liability. Buyer is responsible for all shipping and handling costs.

 

Calibration Fluid Maker


Calibration fluid is necessary to validate a particle counter or used in component endurance tests under a specific contamination level, such as SAE 9. A clean-up filter removes any particulates from the hydraulic fluid to provide a baseline clean starting condition. Measured amounts of particulates are then added to the volume and mixed by a second circuit to create precise calibration fluid. The fluid is made in batches of up to 60 liters.

Additional Information

 

Required Connections

Cold Water:
Connection located at the right rear of the test stand

Electrical
220 volt, 3 phase, 60 Hz with an external ground

Width

24 inches

Depth

40 inches

Height

62 inches

Unit Schematic

This item is sold on an “as-is” basis. The seller makes no claims, representations, or warranties, whether express or implied, as to the quality or the functionality of the item. Furthermore, the seller accepts no liability for the item's safety, reliability, durability, or performance and is not responsible for any physical harm or damage to property as the result of using the item. By purchasing this item, the buyer absolves the seller of any liability. Buyer is responsible for all shipping and handling costs.

 

ATM Sonic Sifter L3P Series E with Horizonal Pulse Accessory

The sifter combines two motions to provide a precise particle separation-a vertical oscillating column of air and a repetitive mechanical pulse to move the material through the sieve. The vertical pulse is combined with the optional horizontal pulse to more quickly and thoroughly sift the material. Sieves can be used to sift particles and dust from 5 to 5600 microns depending on the sieves used. Included are sieves ranging from 2800 to 5 microns with original ATM manuals and literature. We have 29 sieves with specifications upon request.

 

Additional Information

 

Required Connections

Electrical:100 Watts, 120 volts, 1-phase, 60 Hz

Width

12 inches

Depth

10 inches

Height

23 inches

 

This item is sold on an “as-is” basis. The seller makes no claims, representations, or warranties, whether express or implied, as to the quality or the functionality of the item. Furthermore, the seller accepts no liability for the item's safety, reliability, durability, or performance and is not responsible for any physical harm or damage to property as the result of using the item. By purchasing this item, the buyer absolves the seller of any liability. Buyer is responsible for all shipping and handling costs.

Subscribe to Machinery Lubrication